Information

  • Author Services

Initiatives

You are accessing a machine-readable page. In order to be human-readable, please install an RSS reader.

All articles published by MDPI are made immediately available worldwide under an open access license. No special permission is required to reuse all or part of the article published by MDPI, including figures and tables. For articles published under an open access Creative Common CC BY license, any part of the article may be reused without permission provided that the original article is clearly cited. For more information, please refer to https://www.mdpi.com/openaccess .

Feature papers represent the most advanced research with significant potential for high impact in the field. A Feature Paper should be a substantial original Article that involves several techniques or approaches, provides an outlook for future research directions and describes possible research applications.

Feature papers are submitted upon individual invitation or recommendation by the scientific editors and must receive positive feedback from the reviewers.

Editor’s Choice articles are based on recommendations by the scientific editors of MDPI journals from around the world. Editors select a small number of articles recently published in the journal that they believe will be particularly interesting to readers, or important in the respective research area. The aim is to provide a snapshot of some of the most exciting work published in the various research areas of the journal.

Original Submission Date Received: .

  • Active Journals
  • Find a Journal
  • Proceedings Series
  • For Authors
  • For Reviewers
  • For Editors
  • For Librarians
  • For Publishers
  • For Societies
  • For Conference Organizers
  • Open Access Policy
  • Institutional Open Access Program
  • Special Issues Guidelines
  • Editorial Process
  • Research and Publication Ethics
  • Article Processing Charges
  • Testimonials
  • Preprints.org
  • SciProfiles
  • Encyclopedia

technologies-logo

Article Menu

research paper for robot arm

  • Subscribe SciFeed
  • Recommended Articles
  • Google Scholar
  • on Google Scholar
  • Table of Contents

Find support for a specific problem in the support section of our website.

Please let us know what you think of our products and services.

Visit our dedicated information section to learn more about MDPI.

JSmol Viewer

Design and implementation of an anthropomorphic robotic arm prosthesis.

research paper for robot arm

1. Introduction

  • Analyzing the basic requirements for the parameters of an anthropomorphic robotic arm;
  • Designing and developing the anthropomorphic robotic arm and manufacturing and assembling the mechanical parts for construction;
  • The calculation, design and development of the power supply circuits and the control system of the anthropomorphic robotic arm were carried out to ensure the simultaneous control of all drives;
  • Testing the possibilities of connecting to different control systems.

2. Related Works

3.1. prototype design and manufacture, 3.2. control system, 4. results and discussion, 5. conclusions, author contributions, institutional review board statement, informed consent statement, data availability statement, conflicts of interest.

  • Lee, S.U.; Choi, Y.S.; Jeong, K.M.; Jung, S. Development of an underwater manipulator for maintaining nuclear power reactor. In Proceedings of the 2007 International Conference on Control, Automation and Systems, Seoul, Korea, 17–20 October 2007; pp. 1006–1010. [ Google Scholar ] [ CrossRef ]
  • Marinceu, D.; Murchison, A.; Hatton, C. Use of robotic equipment in a Canadian Used Nuclear Fuel Packing Plant. In Proceedings of the 2012 2nd International Conference on Applied Robotics for the Power Industry (CARPI), Zurich, Switzerland, 11–13 September 2012; pp. 139–144. [ Google Scholar ] [ CrossRef ]
  • Bae, H.Y.; Jae-Paeng, I.; Kim, S.; Park, S.Y.; Shin, H.S.; Kim, D.B.; Han, S.H. A Robust Control of Robotic Hand with Nine Axis for Assembly and Handling of Parts in Forging Manufacturing Process. In Proceedings of the 2018 International Conference on Information and Communication Technology Robotics (ICT-ROBOT), Busan, Korea, 6–8 September 2018; pp. 1–3. [ Google Scholar ] [ CrossRef ]
  • Park, C.; Kyung, J.H.; Choi, T.Y.; Do, H.M.; Kim, B.I.; Lee, S.H. Design of an industrial dual arm robot manipulator for a Human-Robot hybrid manufacturing. In Proceedings of the 2012 9th International Conference on Ubiquitous Robots and Ambient Intelligence (URAI), Daejeon, Korea, 26–28 November 2012; pp. 616–618. [ Google Scholar ] [ CrossRef ]
  • Zhang, J.; Wang, W.; Cai, Y.; Li, J.; Zeng, Y.; Chen, L.; Yuan, F.; Ji, Z.; Wang, Y.; Wyrwa, J. A Novel Single-Arm Stapling Robot for Oral and Maxillofacial Surgery—Design and Verification. IEEE Robot. Autom. Lett. 2022 , 7 , 1348–1355. [ Google Scholar ] [ CrossRef ]
  • Tavakoli, M.; Enes, B.; Santos, J.; Marques, L.; de Almeida, A.T. Underactuated anthropomorphic hands: Actuation strategies for a better functionality. Robot. Auton. Syst. 2015 , 74 , 267–282. [ Google Scholar ] [ CrossRef ]
  • Nurpeissova, A.; Tursynbekov, T.; Shintemirov, A. An Open-Source Mechanical Design of ALARIS Hand: A 6-DOF Anthropomorphic Robotic Hand. In Proceedings of the 2021 IEEE International Conference on Robotics and Automation (ICRA), Xi’an, China, 30 May–5 June 2021; pp. 1177–1183. [ Google Scholar ] [ CrossRef ]
  • Sanchez-Velasco, L.E.; Arias-Montiel, M.; Enrique Guzmán-Ramírez, E.; Lugo-González, E. A Low-Cost EMG-Controlled Anthropomorphic Robotic Hand for Power and Precision Grasp. Biocybern. Biomed. Eng. 2020 , 40 , 221–237. [ Google Scholar ] [ CrossRef ]
  • Light, C.M.; Chappell, P.H. Development of a lightweight and adaptable multiple-axis hand prosthesis. Med. Eng. Phys. 2000 , 22 , 679–684. [ Google Scholar ] [ CrossRef ]
  • Plagenhoef, S.; Evans, F.G.; Abdelnour, T. Anatomical Data for Analyzing Human Motion. Res. Q. Exerc. Sport 1983 , 54 , 169–178. [ Google Scholar ] [ CrossRef ]
  • ten Kate, J.; Smit, G.; Breedveld, P. 3D-printed upper limb prostheses: A review. Disabil. Rehabil. Assist. Technol. 2017 , 12 , 300–314. [ Google Scholar ] [ CrossRef ] [ PubMed ]
  • He, Z.; Yurievich, R.R.; Shimizu, S.; Fukuda, M.; Kang, Y.; Shin, D. A Design of Anthropomorphic Hand based on Human Finger Anatomy. In Proceedings of the 2020 International Symposium on Community-centric Systems (CcS), Tokyo, Japan, 23–26 September 2020; pp. 1–5. [ Google Scholar ] [ CrossRef ]
  • Atasoy, A.; Toptaş, E.; Kuchimov, S.; Gulfize, S.; Turpçu, M.; Kaplanoglu, E.; Güçlü, B.; Özkan, M. Biomechanical Design of an Anthropomorphic Prosthetic Hand. In Proceedings of the 2018 7th IEEE International Conference on Biomedical Robotics and Biomechatronics (Biorob), Enschede, The Netherlands, 26–29 August 2018; pp. 732–736. [ Google Scholar ] [ CrossRef ]
  • Devaraja, R.R.; Maskeliūnas, R.; Damaševičius, R. Design and Evaluation of Anthropomorphic Robotic Hand for Object Grasping and Shape Recognition. Computers 2021 , 10 , 1. [ Google Scholar ] [ CrossRef ]
  • Estay, D.; Basoalto, A.; Ardila-Rey, J.; Cerda, M.; Barraza, R. Development and Implementation of an Anthropomorphic Underactuated Prosthesis with Adaptive Grip. Machines 2021 , 9 , 209. [ Google Scholar ] [ CrossRef ]
  • Fajardo, J.; Ferman, V.; Cardona, D.; Maldonado, G.; Lemus, A.; Rohmer, E. Galileo Hand: An Anthropomorphic and Affordable Upper-Limb Prosthesis. IEEE Access 2020 , 8 , 81365–81377. [ Google Scholar ] [ CrossRef ]
  • Kashef, S.R.; Amini, S.; Akbarzadeh, A. Robotic hand: A review on linkage-driven finger mechanisms of prosthetic hands and evaluation of the performance criteria. Mech. Mach. Theory 2020 , 145 , 103677. [ Google Scholar ] [ CrossRef ]
  • Laffranchi, M.; Boccardo, N.; Traverso, S.; Lombardi, L.; Canepa, M.; Lince, A.; Semprini, M.; Saglia, J.A.; Naceri, A.; Sacchetti, R.; et al. The Hannes hand prosthesis replicates the key biological properties of the human hand. Sci. Robot. 2020 , 5 , 46. [ Google Scholar ] [ CrossRef ] [ PubMed ]
  • Leddy, M.T.; Dollar, A.M. Preliminary Design and Evaluation of a Single-Actuator Anthropomorphic Prosthetic Hand with Multiple Distinct Grasp Types. In Proceedings of the 2018 7th IEEE International Conference on Biomedical Robotics and Biomechatronics (Biorob), Enschede, The Netherlands, 26–29 August 2018; pp. 1062–1069. [ Google Scholar ] [ CrossRef ]
  • Owen, M.; Au, C.; Fowke, A. Development of a Dexterous Prosthetic Hand. J. Comput. Inf. Sci. Eng. 2018 , 18 , 010801. [ Google Scholar ] [ CrossRef ]
  • Baspinar, U.; Barol, H.S.; Senyurek, V.Y. Performance Comparison of Artificial Neural Network and Gaussian Mixture Model in Classifying Hand Motions by Using sEMG Signals. Biocybern. Biomed. Eng. 2013 , 33 , 33–45. [ Google Scholar ] [ CrossRef ]
  • Barabulut, D.; Ortes, F.; Arslan, Y.Z.; Adli, M.A. Comparative evaluation of EMG signal features for myoelectric controlled human arm prosthetics. Biocybern. Biomed. Eng. 2017 , 37 , 326–335. [ Google Scholar ] [ CrossRef ]
  • Hakonen, M.; Piitulainen, H.; Visala, A. Current state of digital signal processing in myoelectric interfaces and related applications. Biomed. Signal Processing Control 2015 , 18 , 334–359. [ Google Scholar ] [ CrossRef ]
  • Mott, R.L.; Vavrek, E.M.; Wang, J. Machine Elements in Mechanical Design ; Pearson: New York, NY, USA, 2018. [ Google Scholar ]
  • Grebenstein, M.; Albu-Schäffer, A.; Bahls, T.; Chalon, M.; Eiberger, O.; Friedl, W.; Gruber, R.; Haddadin, S.; Hagn, U.; Haslinger, R.; et al. The DLR Hand Arm System. In Proceedings of the 2011 IEEE International Conference on Robotics and Automation (ICRA), Shanghai, China, 9–13 May 2011; pp. 3175–3182. [ Google Scholar ] [ CrossRef ]
  • Grebenstein, M.; van der Smagt, P. Antagonism for a Highly Anthropomorphic Hand–Arm System. Adv. Robot. 2008 , 22 , 39–55. [ Google Scholar ] [ CrossRef ]
  • Ben-Tzvi, P.; Zhou, M.A. Sensing and Force-Feedback Exoskeleton (SAFE) Robotic Glove. IEEE Trans. Neural Syst. Rehabil. Eng. 2015 , 23 , 992–1002. [ Google Scholar ] [ CrossRef ] [ PubMed ]
  • Abougarair, A.J.; Shashoa, N.A.A.; Elmelhi, A.M.; Gnan, H.M. Real Time Classification for Robotic Arm Control Based Electromyographic Signal. In Proceedings of the 2022 IEEE 2nd International Maghreb Meeting of the Conference on Sciences and Techniques of Automatic Control and Computer Engineering (MI-STA), Sabratha, Libya, 23–25 May 2022; pp. 155–160. [ Google Scholar ] [ CrossRef ]
  • Controzzi, M.; Clemente, F.; Barone, D.; Ghionzoli, A.; Cipriani, C. The SSSA-MyHand: A dexterous lightweight myoelectric hand prosthesis. IEEE Trans. Neural Syst. Rehabil. Eng. 2017 , 25 , 459–468. [ Google Scholar ] [ CrossRef ] [ PubMed ]
  • Young, M.J.; Lin, D.J.; Hochberg, L.R. Brain-Computer Interfaces in Neurorecovery and Neurorehabilitation. Semin. Neurol. 2021 , 41 , 206–216. [ Google Scholar ] [ CrossRef ] [ PubMed ]
  • Mullin, E.; This Man Set the Record for Wearing a Brain-Computer Interface. Wired 2022. Available online: https://www.wired.com/story/this-man-set-the-record-for-wearing-a-brain-computer-interface/ (accessed on 1 September 2022).
  • Robohand. Hand and Forearm Prototype. YouTube. Available online: https://www.youtube.com/watch?v=PXw_nXA1t0c (accessed on 30 July 2022).
  • Motion Capture Glove Frame. YouTube. Available online: https://www.youtube.com/watch?v=tT_MFeVPESs (accessed on 30 July 2022).
  • Motorica Manifesto Hand. BionicsForEveryone.Com. Available online: https://bionicsforeveryone.com/motorica-manifesto-hand/#grip-patterns-control (accessed on 30 July 2022).
  • 8E70—bebionic Hand EQD. Ottobock. Available online: https://www.ottobock.com/en-us/product/8E70 (accessed on 30 July 2022).

Click here to enlarge figure

ProjectDoFNumber of Actuators
Anthropomorphic robotic arm2217
Robotic arm [ ]206
Robotic arm [ ]205
Robotic arm [ ]185
Robotic arm [ ]153
Galileo Hand [ ]156
Robotic arm [ ]116
Hannes hand [ ]91
MyoAdapt Hand [ ]106
ALARIS hand [ ]66
Robotic arm [ ]107
ProjectAnthropomorphic Robotic ArmBebionic 3 (England)Motorica Manifesto Hand (RF)
Mass, of the arm part kg0.5200.6980.482
maximum static weight, kg124520
battery options, mAh300022001200…3500
degree of freedom (DoF)2566
ParameterThe Required Time to Perform the Flexion/Extension, msFinger Angles of Full CompressionFinger Angles of Full ExtensionProximal PhalanxDistal Phalanx
Little finger0.189°90°90°83°
Ring finger0.189°90°90°82°
Middle finger0.189°90°90°82°
Index finger0.189°90°90°82°
Wrist rotation0.12----
MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

Yurova, V.A.; Velikoborets, G.; Vladyko, A. Design and Implementation of an Anthropomorphic Robotic Arm Prosthesis. Technologies 2022 , 10 , 103. https://doi.org/10.3390/technologies10050103

Yurova VA, Velikoborets G, Vladyko A. Design and Implementation of an Anthropomorphic Robotic Arm Prosthesis. Technologies . 2022; 10(5):103. https://doi.org/10.3390/technologies10050103

Yurova, Valentina A., Gleb Velikoborets, and Andrei Vladyko. 2022. "Design and Implementation of an Anthropomorphic Robotic Arm Prosthesis" Technologies 10, no. 5: 103. https://doi.org/10.3390/technologies10050103

Article Metrics

Article access statistics, further information, mdpi initiatives, follow mdpi.

MDPI

Subscribe to receive issue release notifications and newsletters from MDPI journals

Optimization of a Robotic Arm Using Generative Design

  • Conference paper
  • First Online: 20 September 2022
  • Cite this conference paper

research paper for robot arm

  • V. K. Gowtham 12 ,
  • B. S. Sidharth 12 ,
  • Daniel Schilberg 13 &
  • Arockia Selvakumar Arockia Doss   ORCID: orcid.org/0000-0002-7810-6994 12  

Part of the book series: Lecture Notes in Mechanical Engineering ((LNME))

545 Accesses

1 Citations

In today’s world industrial robot are widely used in various manufacturing operations. But the main drawback of these robots is the excessive use of material to make them structurally rigid, which in turn increases their weight and space occupied by them. This research explores the optimum way to reduce weight and make them structurally rigid by using the generative design method. For the above mentioned purpose industrial robot ABB IRB 6660 is selected and a component (robotic arm) of the robot which has significant weight contribution is selected and the load cases such as force, moment are calculated by performing a thorough study. The forces and moment are validated by performing stress stimulation of robot arm in ANSYS. To perform the optimization of robot arm through generative design, Autodesk Fusion 360 is used, which has inherent functions of working on the generative design on the cloud. In fusion 360, the load cases validated above, preserve geometries, obstacle geometries, constraints, materials and manufacturing methods are defined by the user based on the calculation and literature survey. Multiple designs are generated by the software’s algorithm based on the user defined inputs mentioned above. The various generative design outcomes are studies based on comparing various factors such as material, mass, maximum Von Mises stress, maximum displacement and factor of safety. The best generative design outcome is selected by considering the above factors with weight reduction and structural rigidity as primary goal.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
  • Available as EPUB and PDF
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Similar content being viewed by others

research paper for robot arm

Reconfigurable Design and Structure Optimization of SCARA

research paper for robot arm

Topology Optimization and Additive Manufacturing of Lower Arm of a Robotic Manipulator

research paper for robot arm

Material Optimization of Robotic Arm Using FEM and Rigid Body Dynamics

Oh S, Jung Y, Kim S, Lee I, Kang N (2019) Deep generative design: integration of topology optimization and generative models. ASME J Mech Des 141(11):111405. https://doi.org/10.1115/1.4044229

https://xponentialworks.com/the-next-generation-of-generative-design

Buonamici F, Carfagni M, Furferi R, Volpe Y, Governi L, Generative, pp 144–155. https://doi.org/10.14733/cadaps.2021.144-155

Großmann A, Weis P, Clemen C, Mittelstedt C (2020) Optimization and re-design of a metallic riveting tool for additive manufacturing—a case study. Addit Manuf 31:100892, ISSN 2214-8604. https://doi.org/10.1016/j.addma.2019.100892

Aman B (2020) Generative design for performance enhancement, weight reduction, and its industrial implications. arXiv:2007.14138

Kumaran M, Senthilkumar V (2021) Generative design and topology optimization of analysis and repair work of industrial robot arm manufactured using additive manufacturing technology. https://doi.org/10.1088/1757-899X/1012/1/012036

Jerrin Bright R, Suryaprakash SA, Giridharan A (2021) Optimization of quadcopter frame using generative design and comparison with DJI F450 drone frame. IOP Conf Ser: Mater Sci Eng 1012(1):012019. https://doi.org/10.1088/1757-899X/1012/1/012019

Article   Google Scholar  

Weng F, Gao S et al (2019) A novel strategy to fabricate thin 316L stainless steel rods by continuous directed energy deposition in Z direction. Addit Manuf 27:474–481. https://doi.org/10.1016/j.addma.2019.03.024

Article   CAS   Google Scholar  

ManFredi D, Calignano F et al (2013) “From powders to dense metal parts: characterization of a commercial AlSiMg alloy processed through direct metal laser sintering. Materials 6(3):856–869. https://doi.org/10.3390/ma6030856

Yap CY, Chua CK et al Review of selective laser melting: materials and applications. Appl Phys Rev 2:041101. https://doi.org/10.1063/1.4935926

Horgar A, Fostervoll A et al (2018) Additive manufacturing using WAAM with AA5183 wire. J Mater Process Technol 259:68–74. https://doi.org/10.1016/j.jmatprotec.2018.04.014

Johnnieew Zhong Li, Mohd Rizal Alkahari, Nor Rosli AB et al (2019) Review of wire arc additive manufacturing for 3D metal printing. IJAT 13(3):346–353. https://doi.org/10.20965/ijat.2019.p0346

Popic S, Miloradovic B (2015) Light weight robot arms-an overview. In: Conference: INFOTEH At: Jahorina, March 2015

Google Scholar  

John W, Design strategies for high-speed lightweight robots. http://hdl.handle.net/1853/39076

Kempen K, Thijs et al (2012) L Mechanical properties of AlSi10Mg produced by selective laser melting. Phys Procedia 39:439–446. https://doi.org/10.1016/j.phpro.2012.10.059

https://new.abb.com/products/robotics/industrial-robots/irb-6660

Workspaces Search Autodesk Knowledge Network. https://knowledge.autodesk.com/search-result/caas/CloudHelp/cloudhelp/ENU/Fusion-GetStarted/files/GUID-62FC5305-6B73-407B-82AB-70DFD5F1EF60-htm.html

Asif S, Webb P (2021) Kinematics analysis of 6-DoF articulated robot with spherical wrist. Research Article Open Access Volume 2021 Article ID 6647035. https://doi.org/10.1155/2021/6647035

Dhote PK, Mohanta JC, Nayab Zafar M, Motion analysis of articulated robotic arm for industrial application. https://doi.org/10.1109/ICSEngT.2012.6339325

McKnight M (2017) Generative design: what it is? How is it being used? Why it’s a game changer. KNE Eng 2:176–181. https://doi.org/10.18502/keg.v2i2.612

Buonamici F, Carfagni M, Furferi R, Volpe Y, Governi L, Generative design: an explorative study, pp 144–155. https://doi.org/10.14733/cadaps.2021.144-155

Download references

Author information

Authors and affiliations.

School of Mechanical Engineering, Vellore Institute of Technology, Chennai, TN, India

V. K. Gowtham, B. S. Sidharth & Arockia Selvakumar Arockia Doss

Mechatronics and Mechanical Engineering, Bochum University, Bochum, Germany

Daniel Schilberg

You can also search for this author in PubMed   Google Scholar

Corresponding author

Correspondence to Arockia Selvakumar Arockia Doss .

Editor information

Editors and affiliations.

Department of Mechanical Engineering, Sri Sivasubramaniya Nadar College of Engineering, Chennai, Tamil Nadu, India

K. Rajkumar

Faculty of Engineering, Computing and Science, Swinburne University of Technology Sarawak Campus, Kuching, Sarawak, Malaysia

Elammaran Jayamani

Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, Tamil Nadu, India

P. Ramkumar

Rights and permissions

Reprints and permissions

Copyright information

© 2023 The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd.

About this paper

Cite this paper.

Gowtham, V.K., Sidharth, B.S., Schilberg, D., Doss, A.S.A. (2023). Optimization of a Robotic Arm Using Generative Design. In: Rajkumar, K., Jayamani, E., Ramkumar, P. (eds) Recent Advances in Materials Technologies. Lecture Notes in Mechanical Engineering. Springer, Singapore. https://doi.org/10.1007/978-981-19-3895-5_28

Download citation

DOI : https://doi.org/10.1007/978-981-19-3895-5_28

Published : 20 September 2022

Publisher Name : Springer, Singapore

Print ISBN : 978-981-19-3894-8

Online ISBN : 978-981-19-3895-5

eBook Packages : Engineering Engineering (R0)

Share this paper

Anyone you share the following link with will be able to read this content:

Sorry, a shareable link is not currently available for this article.

Provided by the Springer Nature SharedIt content-sharing initiative

  • Publish with us

Policies and ethics

  • Find a journal
  • Track your research

U.S. flag

An official website of the United States government

The .gov means it’s official. Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

The site is secure. The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

  • Publications
  • Account settings

Preview improvements coming to the PMC website in October 2024. Learn More or Try it out now .

  • Advanced Search
  • Journal List
  • Springer Nature - PMC COVID-19 Collection

Logo of phenaturepg

A robotic arm for safe and accurate control of biomedical equipment during COVID-19

Ernesto iadanza.

1 Department of medical biotechnologies, University of Siena, via Banchi di Sotto 55, Siena, 53100 Tuscany Italy

Giammarco Pasqua

2 Department of Information Engineering, University of Florence, Via di Santa Marta 3, Firenze, 50139 Tuscany Italy

Davide Piaggio

3 School of Engineering, University of Warwick, Library road, Coventry, CV56GB England UK

Corrado Caputo

Monica gherardelli, leandro pecchia.

4 School of Engineering, Campus Biomedico of Rome, Via Álvaro del Portillo 21, Roma, 00128 Lazio Italy

Hospital facilities and social life, along with the global economy, have been severely challenged by COVID-19 since the World Health Organization (WHO) declared it a pandemic in March 2020. Since then, countless ordinary citizens, as well as healthcare workers, have contracted the virus by just coming into contact with infected surfaces. In order to minimise the risk of getting infected by contact with such surfaces, our study aims to design, prototype, and test a new device able to connect users, such as common citizens, doctors or paramedics, with either common-use interfaces (e.g., lift and snack machine keyboards, traffic light push-buttons) or medical-use interfaces (e.g., any medical equipment keypad)

To this purpose, the device was designed with the help of Unified Modelling Language (UML) schemes, and was informed by a risk analysis, that highlighted some of its essential requirements and specifications. Consequently, the chosen constructive solution of the robotic system, i.e., a robotic-arm structure, was designed and manufactured using computer-aided design and 3D printing.

The final prototype included a properly programmed micro-controller, linked via Bluetooth to a multi-platform mobile phone app, which represents the user interface. The system was then successfully tested on different physical keypads and touch screens. Better performance of the system can be foreseen by introducing improvements in the industrial production phase.

This first prototype paves the way for further research in this area, allowing for better management and preparedness of next pandemic emergencies.

Introduction

The cause of COVID-19 pandemic, the SARS-CoV-2 virus, is still circulating and differentiating in variants with different levels of aggressiveness and contagiousness [ 1 ]. This novel strain of coronavirus has been seriously affecting the daily lives of citizens, worldwide, for approximately the past two years. Back at the onset of the disease, in the midst of the age of globalization, in which people and goods can easily and quickly travel around the world, no one was expecting the advent of a new phase, that of the social distancing and the closing of the borders. Since the start of the pandemic, infection prevention and control (IPC) measures, such as the frequent hand sanitizing with alcohol-based rubs, together with the use of face masks or respirators, have become one of the most effective means to prevent the COVID-19 diffusion. In fact, SARS-CoV-2 can be transmitted via direct (if deposited on people) or indirect (if deposited on objects) contacts and airborne (via droplets and aerosols) routes [ 2 ]. Contrasting debates around the actual transmission routes of SARS-CoV-2 are still ongoing in the scientific community [ 3 ]. Chin et al. [ 4 ] showed that the infectious form of SARS-CoV-2, under laboratory conditions, is traceable on surfaces for several hours depending on the material: less than 3 hours on printing paper or toilet paper, up to 24 hours on wood and textiles, and for up to 3-4 days on smooth surfaces (e.g., steel and plastic). For these reasons, since the onset of COVID-19, more and more individuals have contracted the virus simply by getting in contact with infected surfaces. Certainly, this poses a serious threat for healthcare workers, who come into contact with several potentially infected surfaces during their shifts. Although in late 2020, vaccination programs started, the level of coverage is still far from desired values. Although for high-income and upper-middle income countries, respectively 67.9% and 66.5% of the population has completed the vaccination cycle (with Gibraltar, Portugal, United Arab Emirates, Malta, Singapore, Chile, Cayman Islands, Cuba, Spain, South Korea, and Iceland overshooting 80%) (as of 2 December 2021), for low-income and lower-middle income countries, respectively only 1.4% and 27.9% of the population did. Overall, globally, only 43.8% of the population completed the vaccination cycle ( https://ourworldindata.org/grapher/share-people-fully-vaccinated-covid ). Moreover, the reduced transmission from breakthrough infections in vaccinated people is still being studied and will require more observational studies following household contacts [ 3 ]. Consequently, IPC measures will still be vital to avoid extreme rises in cases and hospitalisations. In light of this, the idea presented in this paper is to design and develop a device able to put in communication the user with a paired electromedical equipment and/or common use interfaces. This novel device is intended to avoid direct contact between users and machine interfaces. Initially, the focus of this study was addressed to three examples of medical devices, i.e., an electrocardiograph, a bedside monitor, and an oxygen concentrator. Afterwards, the focused was shifted to different types of physical keypads and touch screens, because the problem of avoiding contact with contact surfaces is the same and so are the corresponding solutions. In fact, it would be possible to manage electromedical equipment, as well as common-use interfaces, from long distance, through a wireless connection, for instance using Bluetooth or WiFi technologies. Several projects are already available, and many others are still in development, with regard to either tele-operated robots or remote-controlled apparatuses, even in the medical field. For instance, Wang et al. present a review of current researches and future development trends of intelligent robots [ 5 ]. In order to provide specificity, the focus must be on a project related to technologies designed to prevent the diffusion of infectious diseases and technologies conceived for remote interaction with buttons, toggles, sliders and so forth. A thorough analysis of the healthcare structures is important to spot possible risks [ 6 ]. As reported by “Federazione Nazionale degli Ordini dei Medici e degli Odontoiatri” (FNOMCeO) and “Istituto Superiore di Sanitá” (ISS), in Italy, more than 124,000 healthcare workers have been infected with COVID-19 and, of these, 341 doctors and paramedics died from it ( https://portale.fnomceo.it/ , https://www.epicentro.iss.it/coronavirus/bollettino/Bollettino-sorveglianza-integrata-COVID-19_10-marzo-2021.pdf .

Hence, a great deal of efforts, by countless research teams, has been focused in developing different devices for the safeguarding of healthcare workers, worldwide. In 2016, a work carried out by Kraft raised the issue of doctors and paramedics’ safety, within an infectious diseases context [ 7 ]. In this study, Kraft proposes the use of a tele-operated robot, previously developed by himself and Kraft and Smart [ 8 ], and analyses which tasks such a machine should accomplish, for instance, in an Ebola treatment unit. One of the surfacing issues is the problem of visibility, for which the authors performed some trials in both the conditions of visibility and no-visibility between the operator and the patient-simulating person. In the paper by Miseikis et al. [ 9 ], a mobile robot platform is designed and described: it is equipped with a multi-function arm, intended for the Human-Robot Interaction (HRI) and for personal care assistant tasks. This robot is able to both assist and interact with people. Lanza et al. propose an improvement of tele-health system features in order to allow patients support, in the same way of human caregivers [ 10 ]. Their idea is to provide the patient with requested assistance either in simple clinical assisting scenarios or emergency ones. In the case of a large-scale diffusion, such as the COVID-19 pandemic, their suggestion goes towards the reduction of the contagion risk, by the use of remotely controlled multi-agent architecture for intelligent medical care. The paper by Tavakoli et al. [ 11 ] show how robotic and autonomous systems and smart wearables can complement and support healthcare delivery and staff during the COVID-19 pandemic. The main idea is to reduce the infectious disease transmission risks, for frontline healthcare workers, through a safe-distance remote control. Yang et al., within the so-called “Healthcare 4.0” design a novel homecare robotic system (HRS) based on the Cyber-Physical Systems (CPS) [ 12 ]. With this new concept of healthcare, all operations are performed remotely. Great technological progresses are required until such a solution could be applicable. Another research carried out by Yang et al. [ 13 ] proposes a new tele-robotic system for remote care operation in isolation wards. That system consists of two components, i.e., a teleoperation system and a telepresence system. They hope to reduce infections thanks to the reduction of contact between infected patients and healthcare workers. The review by Zeng et al. summarizes the main applications that robots have as part of different contexts [ 14 ]. With regard to researches intended to develop devices for remote interaction with different buttons types, an interesting investigation was carried out by Wang et al. [ 15 ]. In this work, authors perform a systematic categorization of buttons and switches, taking over 600 button examples, found at home and workplace environments, as specimens. These researchers designed a subsystem in order to recognise, localise and detect buttons, with high reliability. They realized a tip system able to actuate pull buttons or turn knobs, by remote controlling. In 2010, in Taiwan, Wang and his staff presented a robotic arm prototype, designed on the top of a wheeled robot, able to recognise numbers or signs and to push buttons [ 16 ]. In their project, authors involved the use of a micro-camera, placed on the tip of the arm, intended for the image processing and pattern recognition. By means of inverse kinematics, researchers calculated the angle of each robot link in order to successfully press the desired button. Their trials were performed on the elevator panel, the robotic arm was controlled by a computer. We recall that our idea is to project and develop a device able to put in “telecommunication” the user with an electromedical equipment and/or a common use interface. According to European regulations, in order to market a medical device, its design has to be deemed safe by the regulatory bodies of the country under consideration. In this regard, to certify the device as safe, the producer company has to refer to the national versions of international standards, applicable to the concerned device. Compliance with these standards accounts for documentation necessary to demonstrate the actual safety of the designed product. For this reason, it is necessary to apply design principles during the study early stages of the device, paying particular attention to all aspects that guarantee regulatory compliance and certification of the medical device. In order to meet the European requirements it is necessary to adopt a multi-step approach, that is not necessarily a serial process, throughout the cycle, such as [ 17 ]: (1) analyze the device to determine which directive/regulation is applicable, (2) identify the applicable essentials requirements list, (3) identify any corresponding harmonized standards, (4) confirm that the device meets the essential requirements/harmonized standards and document the evidence, (5) classify the device, (6) decide on the appropriate conformity assessment procedure, (7) identify and choose a notified body (NB), (8) obtain conformity certifications for the device, (9) establish a declaration of conformity and, lastly, (10) apply for the CE mark.

For medical devices, the International Standards Organization (ISO) established two important standards: ISO 13485 and ISO 14971 [ 17 ]. ISO 13485 presents the requirements for a comprehensive medical device designing and manufacturing Quality Management System (QMS). ISO 14971 “Medical devices - Application of risk management to medical devices” was drawn up in 2019 [ 18 ]. This standard explains a procedure by which a manufacturer can:

  • Identify the hazards and hazard situations associated with medical devices,
  • Estimate and evaluate the associated risks,
  • Control the risks, and last,
  • Monitor the effectiveness of the adopted risk control measures.

As stated in [ 18 ], such a process must include: risk analysis, risk evaluation, risk control and production and post-production activities. After those procedures, it is necessary to carry out the risk evaluation (for each identified hazard situations, determining the acceptability or not of those), the risk control option analysis (determining appropriate risk control measures in order to reduce the risks to an acceptable level), the implementation of the risk control measures and the residual risk evaluation (following the risk acceptability defined criteria defined in the risk management plan, drawn up by the manufacturer). Once that is done, the manufacturer must verify the effectiveness of the selected risk control measure, considering also the risk arising from those measures, evaluating then the overall residual risk and reporting everything in the “Risk Management” review.

The International Electrotechnical Commission (IEC), is the leading global organization that prepares and publishes International Standards, Technical Specifications, and so on, with the aim of promoting international cooperation about all the aspects regarding electrical and electronic fields standardization. According to the agreements, the IEC and the ISO collaborate closely in the preparation of standards. Among the documents drawn up by IEC, the 60601-1 is the one concerning medical electrical equipment and medical electrical systems, with particular attention to “general requirements for basic safety and essential performance” [ 19 ]. Based on the above standards, we proceeded with the design of the mechanical structure of the aforementioned device. We selected two structural components considered optimal for our purpose: a robotic-arm structure and a x-y-z-axis plotter. 3D models were realised for both the components. Following 3D printing, the robotic-arm was assembled and the actuator motors were programmed via Arduino Mega microcontroller. A multi-platform app, communicating with Arduino, was developed using Ionic 5, Angular and Capacitor frameworks. In accordance to ISO 14971 and IEC 60601-1 regulations, we also carried out a Preliminary Hazard Analysis (PHA) of our device.

Methods and tools

The aim of our study is to design and develop an automated or robotic system allowing to reduce people’s contact with contaminated surfaces of a selected medical equipment. The automated system has to put in communication the user with the medical equipment and/or common-use surface. Our device is intended to avoid direct contact between users and machine interfaces. Through a wireless connection, for instance using Bluetooth or WiFi technologies, between a remote device, such as a mobile phone app or a programmed joystick, and the designed device, it would be possible to manage a medical equipment, but even common-use interfaces from long distance. Our prototype is composed of two main components:

  • An automated robotic system, driven by a micro-controller,
  • A mobile phone app, that remotely communicates with the micro-controller.

In light of this, the technologies and tools used for the design and realization of such a prototype are:

  • Unified Modeling Language (UML),
  • Computer Aided Design (CAD),
  • Additive Manufacturing (AM) and Rapid Prototyping (RP),
  • Integrated Development Environment (IDE).

Structural solutions

We selected two structural solutions, considered optimal for our purpose: a 3-axis plotter and a robotic-arm structure.

3-axis plotter

A completely new 3D model was realised for the plotter solution (Fig. ​ (Fig.1), 1 ), using SolidWorks software. Such a model is composed of: a stepper motor and two toothed pulley-belt systems, in order to allow movements on x-axis (horizontal movements) of a linear guide; a stepper motor with a toothed pulley-belt system that moves a linear guide allowing movements on y-axis (horizontal movements); a micro-servo motor allowing movements on z-axis (vertical movements) of an interchangeable stylus, intended for contact with different kind of surfaces (pushbutton, touch screen, soft-touch screen and so on).

An external file that holds a picture, illustration, etc.
Object name is 12553_2022_715_Fig1_HTML.jpg

Schematic representation of the 3-axis plotter model

The robotic-arm model

The robotic-arm model was chosen as best solution due to its versatility and adaptability to the most diversified situations and environments. To achieve this, at first, we conducted a research of ready-made robotic arms available on the web and we chose a four Degree-of-Freedom (DOF) model, easily purchased in the main online seller and supplier web-pages. Such a model is realised by laser-engraved wood, it is easily assembled and makes use of three micro-servo motors, allowing movements in the space, and an extra micro-servo, allowing the grasping. Then, in order to allow a more reliable and faster testing and to improve the quality of our model, we also carried out a web-search of 3D printable robotic arm models. Among the opensource projects available on the web, we chose the model shown in Fig. ​ Fig.2. 2 . Such a model uses four micro-servo motors: three motors for motion through space and one for the grasping function. The robotic-arm was assembled following the 3D printing with Polylactide Acid (PLA) filament. We used PLA, that is a polyester and a thermoplastic polymer, with the characteristic of being biodegradable and derived from renewable sources. PLA is applied to several biomedical fields and is particularly cost-effective, since it results actually easy to produce and dispose, and there are different types in terms of molecular weight, with characteristic modulus of elasticity. The actuator motors were programmed by Arduino Mega microcontroller.

An external file that holds a picture, illustration, etc.
Object name is 12553_2022_715_Fig2_HTML.jpg

Representation of the 4-DOF 3D printable robotic arm model

System design

Diagrams created with the UML were created in order to portray the behaviour and structure of our system. UML is a general purpose modelling language with the main aim of defining a standard solution to visualize the way a system has been designed. It is not a programming language, but rather a visual language. As reported by International Business Machines Corporation (IBM) ( https://developer.ibm.com/articles/an-introduction-to-uml/ ), the Object Management Group (OMG) adopted UML as a standard in 1997. It has been managed by OMG ever since. International Organization for Standardization (ISO) published UML as an approved standard in 2005. The language has been revised over the years and is reviewed periodically. UML diagrams are useful, since they help with modelling, design and analysis, and it is possible to categorise them hierarchically. In the following figures we represent three diagrams among the UML diagrams:

An external file that holds a picture, illustration, etc.
Object name is 12553_2022_715_Fig3_HTML.jpg

A schematic of the UML class diagram of our device model concept

An external file that holds a picture, illustration, etc.
Object name is 12553_2022_715_Fig4_HTML.jpg

A schematic of the UML use case diagram of our device model concept

An external file that holds a picture, illustration, etc.
Object name is 12553_2022_715_Fig5_HTML.jpg

A schematic of the UML interactions sequence diagram of our device model concept

In our class diagram (Fig. ​ (Fig.3) 3 ) we identified four main components: Remote Controller, Local Controller, Mediator Device, General Device. The Remote Controller is intended to be a joystick or a mobile app, easily installed on any mobile phone, to remotely control the Mediator Device, composed of a Support Frame and an Actuator, by means of a Local Controller (the selected micro-controller), which includes few different modules (e.g. Bluetooth module, power supply and so forth). The Mediator Device is the tool directly in contact with the General Device, which might be a medical equipment as well as a civilian equipment, as already stated. In the Use-Case diagram we pinpointed the different tasks that our model concept might accomplish: motion through 3D space for grabbing physical objects (i.e. knobs or sliders), turning objects (such as knobs), and pushing them (physical and non-physical buttons). Finally, in the Interaction Sequence diagram we hypothesized how the functions might be performed and in which logical order. Obviously, all the interactions start from the Remote Controller, come through the Local Controller that deals with the Actuator motion and its interaction with the General Device. In order to make our model concept even clearer, we developed a Model-View-Controller (MVC) functional diagram (Fig. ​ (Fig.6). 6 ). Model-View-Controller is a software design pattern commonly used for developing user interfaces that divides the related program logic into three interconnected elements. This is done to separate internal representations of information from the ways information is presented to and accepted from the user ( https://www.artima.com/articles/dci_vision.html ). As shown in Fig. ​ Fig.6, 6 , we defined all the internal components of each part of our model concept. All the internal components of the actuator, except the power supply, directly communicate with the micro-controller. The Remote Controller communicates with the micro-controller via Bluetooth.

An external file that holds a picture, illustration, etc.
Object name is 12553_2022_715_Fig6_HTML.jpg

Model-View-Control (MVC) Functional diagram of our model concept

The microcontroller

In order to program and control our prototype we decided to use an Arduino Mega 2560 micro-controller ( https://www.robotstore.it/rsdocs/documents/Arduino_Mega_overview.pdf ). The Arduino Mega is a microcontroller board based on the ATmega1280 microprocessor. It is provided with 54 digital input/output pins: 14 can be used as Pulse Width Modulator (PWM), 16 for analog inputs, and four for Universal Asynchronous Receiver/Transmitter (UART) hardware serial ports. It is equipped with a 16 MHz crystal oscillator, a Universal Serial Bus (USB) connection, a power jack, an “In Circuit Serial Programming” (ICSP) header, together with a reset button. Everything needed to support the microcontroller is onboard. It can boot either connected to a computer, with a USB cable, or powered externally, either with a Alternating-Current(AC)-to-Direct-Current(DC) adapter or a battery ( https://www.robotstore.it/rsdocs/documents/Arduino_Mega_overview.pdf ).

Such a microcontroller comes with an open-source Integrated Development Environment (IDE), called Arduino Software, or Arduino IDE. This open-source IDE makes it easy to write code and upload it to the board. It runs on Windows, Mac OS X, and Linux. The environment is written in Java and based on Processing and other open-source software ( https://www.arduino.cc/en/Main/Software ). Arduino company provides everyone with an online version of their open-source IDE (Arduino Web Editor). It allows you to save your sketches in the cloud, having them available from any device and backed up. In such a way, it is possible to always have the most up-to-date version of the IDE without the need to install updates or community generated libraries. In order to work offline, we opted for the offline version of their IDE. Arduino IDE software makes it possible to program Arduino, in order to control four SG90 micro servo motors ( https://www.robotstore.it/en/Servo-micro-TowerPro-SG90-9g ) by means of a HC-05 Bluetooth module ( https://components101.com/sites/default/files/component_datasheet/HC-05%20Datasheet.pdf ). Micro servo are tiny and lightweight with high output power. They can provide a rotation of approximately 180 degrees, 90 in each direction. HC-05 Bluetooth module is an easy way to use Bluetooth Serial Port Protocol (SPP) module, designed for transparent wireless serial connection setup. It uses a frequency band centered in 45GHz; the data transfer rate can vary up to 1 Mbps and in range of ten meters. Its communication is via serial communication, which is an easy way to interface with controller or PC.

The remote controller

With the aim to remotely control and communicate with the Arduino board, we decided to develop a mobile application (app), that was initially developed using Android Studio, the official Integrated Development Environment (IDE) for Google’s Android operating systems, designed specifically for Android development. Subsequently, for the purpose of making our mobile app available for any mobile devices, we decided to develop a cross-platform app. Cross-platform app development frameworks allow developers to create mobile applications that are compatible with several operating systems. Among the various cross-platform app frameworks, we have analysed some of the most competitive, mature, and top-performing frameworks available today: Xamarin ( https://dotnet.microsoft.com/apps/xamarin ), React Native ( https://reactnative.dev/ ), Flutter ( https://flutter.dev/ ), Ionic ( https://ionicframework.com/docs ), Capacitor ( https://capacitorjs.com/ ). Our final decision was Ionic plus Capacitor. The former is an open-source HTML5 SDK that helps developers build native-feeling mobile apps using web technologies like HTML, CSS, and Javascript. The latter is an open source project that uses Progressive Web App (PWA) technology to run modern Web Apps natively on iOS, Android, and the Web, while also providing an interface for accessing Native SDKs and Native APIs on each platform. Thanks to the coupled use of these two frameworks, we were able to develop a cross-platform mobile app, allowing us to remotely control our robotic arm.

Remote visualization of the robotic arm work

The actuator is designed to be remotely operated. For instance, with a clear reference to the pandemic situation, it must be possible for the user to control the robotic arm from outside the room where it is placed. This will highly reduce a possible infection risk for the user (e.g. physician or nurse) as well as the need for personal protective equipment. The system has been provided with a camera module to provide the user with a remote visual feedback while operating the robotic arm. For this purpose, we employed a ESP32-CAM module, that is provided with internal Bluetooth and WiFi modules ( https://media.digikey.com/pdf/Data%20Sheets/DFRobot%20PDFs/DFR0602_Web.pdf ). The app has been implemented with a dedicated code to use the camera module, thus giving the end-user an awareness of which button is really going to be pressed, and reducing the error margin.

System testing

Once the prototype was finalised, the system was setup and calibrated to perform several ad-hoc tests to evaluate its performance and effectiveness. Such tests were performed on several test panels containing various kinds of buttons in terms of shape and stiffness. In particular, six different interfaces, namely three physical keypads and one touch screen, i.e., Arduino Membrane Switch Module, Casio Calculator Panel, Lexmark Printer Panel, and Lexmark Printer Touchscreen, were selected to this purpose. Tests were performed both with the original robotic tip and an added-on touch pen. Firstly, the overall responsiveness of the different types of buttons was assessed on all the selected interfaces. Secondly, for all the interfaces that were responsive, repeated measures were performed to measure the repeatability and performance of the system. Only the printer touchscreen and the calculator made it to the second part of the tests. Consequently, for testing the robotic arm/printer touchscreen interaction, ten consecutive trials were performed on the same button. As regards the testing of the robotic arm/calculator interaction, ten consecutive trials were performed on eight buttons, i.e., “.”,“,” “2”, “5”, “8”, “=”, “-”, “:”, and “AC”. The number of successful trials was recorded to calculate performance and repeatability.

Risk management

Since the proposed device is designed to be also used in medical settings, standards concerning medical devices and electromedical equipment were followed, although a proper risk management according to European regulations was out of the scope of this work. As graphically described in Fig. ​ Fig.7, 7 , the ISO 14971 and IEC 60601-1 standards (see Section 1 ) make up the pillars in designing electromedical equipment.

An external file that holds a picture, illustration, etc.
Object name is 12553_2022_715_Fig7_HTML.jpg

A schematic graph representing regulatory references of each medical device developing steps

Indeed these norms provided us with the grounding principles to be followed with reference to “Research and Development” (R &D) and “Design & Validation” (D &V) phases. In accordance with them, we firstly carried out a Preliminary Hazard Analysis (PHA). This analysis is dedicated to analyzing prior experience or knowledge about hazards or failures, in order to identify future and foreseeable hazardous situations, hazards and any kind of events that may result in harm for the end-user (in particular for patient and operator). In order to analyse existing systems or to prioritise hazards, in those cases in which circumstances prevent a more extensive technique from being used, the PHA results to be indeed useful in designing products, processes and facilities. This tool can be used to evaluate the types of hazards for the general product type, then the product class and, finally, the specific product, as well. In early phases of project concept and design development, in which information on design details or operating procedures are still uncertain, PHA is most commonly used. For this reason, it is often put in place as a precursor to further studies. Typically, hazards identified in the PHA are further assessed with other risk management tools (for instance risk ranking and filtering or statistical tools) [ 20 ,  21 , 22 ]. For each of the identified hazards, the method includes the following activities:

  • Identification of the possibility of the risk event occurring;
  • Qualitative evaluation of the extent of possible injury or damage to health that could result;
  • Relative ranking of the hazard using a combination of severity and likelihood of occurrence;
  • Identification of possible remedial measures.

The main configuration of the proposed device is sketched in Fig. ​ Fig.8. 8 . With the aim to test the device, other components have been used, such as a Membrane Switch module, a Liquid Crystal Display (LCD) screen module (LCD1602) and a camera module (ESP32-CAM).

An external file that holds a picture, illustration, etc.
Object name is 12553_2022_715_Fig8_HTML.jpg

A main hardware configuration sketch of our device (in the sketch is reported Arduino UNO instead of Mega, since it could be used that model as well)

Preliminary hazard analysis

As mentioned above, in order to obtain a product that is safe by design, we carried out a PHA, with reference to the standard for risk management of medical devices (ISO 14971 [ 18 ] and to the general norm for electromedical equipment, IEC 60601-1 [ 19 ]. An abstract of this PHA is reported in Table ​ Table1. 1 . As a first step, we analyzed three classes of hazards categories, according to [ 18 ]: energy hazards, performance-related hazards and biological and chemical hazards. Then, we focused on the model components: an actuator, a support frame, a local controller and a remote controller. For each of these components, we hypothesized several different hazards for each hazard category. We grouped these hazards by type (e.g. environmental hazards, immunological agents, electromagnetic emission, and more). For each of them we defined five properties: foreseeable sequence of events or hazardous situations, typology of resulting harm (e.g. injury, thermal burns, allergic effect, etc.), severity (by giving a value in a 1-to-5 range), probability of occurrence (by attributing a 1-to-5 value), and possible risk-mitigation interventions (for instance using alarm or choosing suitable materials). The 1-to-5 ranges for both severity and probability of occurrence are reported in Table ​ Table2. 2 . Following this preliminary analysis, risks can be ranked and filtered. To each risk is associated a value of severity and a probability of occurrence (likelihood). By multiplying the given severity value by the given likelihood value, the risk value is obtained. A risk matrix, like the one in Table ​ Table3, 3 , can be used to establish a risk acceptability threshold. We chose the threshold value of 9, corresponding to the product of “occasional” (likelihood) and “serious” (severity). Risk values above this value are then classified as not acceptable, and in that case risk reducing measures are required. Risk values between eight and four are considered acceptable, but further investigations are advisable. Risk values below three are accepted. In our PHA are reported some potential risk controls, for each hazard ( ​ (2. 2 . A further risk assessment procedure is necessary to verify if all the risks are acceptable after these control measures, or if new countermeasures should be put in place. A full risk analysis is out of the scope of this article, but will be needed when the proposed prototype will be engineered by a manufacturer, to be CE marked and put on the market [ 20 , 22 ].

Abstract of Preliminary Hazard Analysis

Energy HazardsActuatorShape and geometryAccidental contact with stylus leads to get hurtInjury23Stylus design, use instructions/warnings
Shape and geometry / MaterialsThe stylus falls down, detaching itself or not from Frame SupportInjury23Stylus-frame support design avoiding detaching, use instructions/warnings
High pressureContact between Stylus and Machine leads to damageDamage of stylus/machine43Stylus material design, haptic system, alarm
Electrical shockStylus transfers electric current to accessible surfaces during operationInjury22Stylus design, use instructions/warnings, alarm
MisuseUser places his own hand between stylus and “machine”Injury25Stylus design, use instructions/warnings
Unsuitable stylusUnsuitable stylus is usedStylus and/or ”machine” damaging34Stylus material design, haptic system, alarm, use instructions/warnings
Flammability/ ExplosivenessParts catch on fire/explodeInjury, part damaging42Stylus design, use instructions/warnings, alarm
Frame SupportShape and geometryContact with Frame Support leads to get hurtInjury23Frame support design, use instructions/warnings
Shape and geometry / MaterialsThe Frame support falls downInjury, sub-assemblies damaging23Frame support design, use instructions/warnings
MisuseFrame support is incorrectly fixed on a “machine”Injury, part damaging25Frame support design, use instructions/warnings
Local ControllerHot surfacesContact with local controller leads to skin burningThermal burns24Alarm, use instructions/warnings
Shape and geometryContact with Local Controller leads to get hurtInjury23Local controller design, use instructions/warnings
Shape and geometry / MaterialsThe Local Controller falls downInjury24Local controller design, use instructions/warnings
Electrical shockLocal controller transfers electric current to accessible surfaces during operationInjury23Local controller design, use instructions/warnings, alarm

Severity and Probability of Occurrence levels definition

SeverityNegligible (1)Inconvenience, or temporary discomfort
Minor (2)Temporary injury or impairment not requiring professional medical intervention
Serious (3)Injury or impairment that requires professional medical intervention
Critical (4)Permanent impairment or life-threatening injury
Catastrophic (5)Patient or operator death

Risk Matrix

An external file that holds a picture, illustration, etc.
Object name is 12553_2022_715_Tab3_HTML.jpg

The arduino code

The Arduino code is developed in order to program the board and all the modules connected, it is made up of four sections. The first one includes the required libraries and defines variables and constants. The void setup() section includes all useful settings required later. The tasks that the Arduino board accomplishes, are programmed in the void loop() section. The last part of the code implements the computing functions called by the void loop() . The developed code is included in the supplementary materials.

The cross-platform mobile app

Thanks to the combined use of the above mentioned Ionic and Capacitor frameworks we were able to develop a cross-platform mobile app, that allows to remotely control the robotic arm. The app is multi-tab: after selecting the Bluetooth module to connect to (HC-05 module in our case) the interface shows three tabs. The first one allows to send text by typing on the phone keyboard (meant as a testing tool); the second one is called “Manual Controller” and allows to send commands to Arduino for moving the different servo motors (i.e., up, down, right, left, forward and backward); the last tab graphically reproduces a real keypad, allowing the user to add as many customised keypads as desired, enabling to choose several features such as the dimension of the custom keypad (i.e., 3x3, 4x3, 4x4 etc.) or the number of servo motors to control. It is then possible to activate and customise each button individually. A modal page allows to define a button’s icon (Ionic platform provides several great-looking pre-defined icons), its label (alphanumeric characters or some symbols), and colour, as well as the initial position for each servo motor to control. Once enabled the “customisation enabler” slider, it is possible to “Test” the button, moving servo motors to the defined positions, or to close the page and automatically save the desired button features. Once the keypad setup is finished, it is possible to “Save” the custom keypad and then to “Add” a new one. Once finished, the “customisation enabler” slider can be switched off and the selected keypad is ready to be selected from a drop-down menu and used. The following Fig. ​ Fig.9 9 shows all the different tabs of the developed cross-platform app.

An external file that holds a picture, illustration, etc.
Object name is 12553_2022_715_Fig9_HTML.jpg

Different tabs of our app: A The available Bluetooth modules list page; B Typing bar page; C Manual Controller tab; D Keypad customization interface; E Modal page for button features definition; F Example of customised keypad

In order to test and evaluate performances and effectiveness of our prototype, we carried out the system setup and calibration and performed some trials using test panels containing buttons of various types, shapes, and stiffness. We employed six different interfaces which our arm had to interact with: three physical keypads and three touch screens.

Robotic arm and app setup

To apply the method to a new environment, a manual setup procedure must be performed to populate a database of button panels, using the above described procedure. The process is relatively fast and the environment is minimally altered. For example, completing annotation, calibration, and information entry for a general device panel with 16 to 20 buttons takes about 20 minutes. Servo motors position setting requires more time, but the whole setup of a new keypad takes less than one hour. The procedure consists of the following steps:

  • Definition and setting up of robotic arm position relative to the keypad being tested;
  • Setting up of an interface resembling the real keypad, on the mobile app;
  • Definition of servo motors positions for each button.

Environmental Annotation and Calibration - At first, we fixed the robot arm base on a platform: its layout allows to easily fix the support frame using some screws. The center of the base has been fixed at a distance of 20cm from the wall containing the keypads to be operated. The base was positioned at 47cm above ground, keypads at 64cm. The robotic arm maximum extension is 23cm outward, allowing the robot to press buttons placed on a 20cm-radius semi-sphere, being it moved by micro-servo motors with 180-degrees motion ability (90 degree in both directions). By testing with these settings, it resulted that this robot is able to frontally push buttons placed in a range between 46cm to 62cm above the ground (approximately equal horizontal range).

Keypad customization on the mobile app - Once all the spatial settings have been configured, we proceeded to replicate the test keypads on the dedicated mobile app tab. As already stated, this step is fairly quick, taking roughly one hour to replicate the calculator panel, composed of 20 buttons (smallest buttons were excluded), and a little less for the other simpler panels. To set the positions of each micro-servo motors for each button, we made use of the manual controller app tab that aided to find them easily.

Tests of pushing buttons and related results - Upon completing the setup phase, we proceeded testing the five different keypads as anticipated in the methods. First of all, we tested the switch membrane module of Arduino. With the exception of few sporadic events, our robot was not able to press any buttons and the repeatability of the task was inconsistent. The keypad button stiffness is too high to allow the robot to complete the required function. Moreover, our model is not rigid enough in comparison to such a keypad and it tends to slip on it. Those tests have been performed using both the wooden 3D robotic arm, and the PLA one, as it is possible to see in Fig. ​ Fig.10 10 .

An external file that holds a picture, illustration, etc.
Object name is 12553_2022_715_Fig10_HTML.jpg

Photos of tests with the switch membrane module of Arduino and both the wood and the PLA models

After that, we tested a printer panel (printer model Lexmark CS727). Similarly to the previous keypad, buttons of that panel are too stiff for our robotic arm that, once again, tends to slip on it. No buttons have been pushed by the robotic arm during tests. Differently, the robot was well capable to press the touch screen of the printer without any issues, showing a sensitive and responsive behaviour. We queried the robot to press the same button ten times and it worked correctly every time (success rate of 100%). Considering that the actuator probe is suited for grabbing and holding small objects but it is not appropriate as pointer, meant to press any kind of buttons, we mounted a rubber “touch pen” on the robotic arm clamp. The interaction between the tip and the interfaces (calculator keypad and printer touch screen) seemed to qualitatively improve. Finally, we tested the ability to operate a calculator panel. The button stiffness is such that the robotic arm could readily and effectively push those buttons. We tested the following buttons: “.”, “2”, “5”, “8”, “=”, “-”, “:” “AC”. Each button was pressed ten times in a row, for a total of 80 trials. These trials have been performed successfully 76 times over 80, with a repeatability/success rate equivalent to 95%. The robotic arm was able to press buttons with and without the pen mounted on.

Discussions

The system prototype (app and robotic arm) presented in this manuscript was developed by integrating different engineering methods. This system prototype is conceived for decreasing the contact events with common surfaces such as the interfaces of medical devices and civilian ones (e.g., elevator panels). In fact, it is designed in a way so that the users can interface themselves with such devices, via our mobile app, installed on their smartphone, which communicates with our robotic arm that is installed on the device/surface of interest. This communication can rely either on Bluetooth or WiFi. This long-distance interaction is enhanced by the camera module, mounted on the robotic arm, which allows for visual feedback of the button pressed on the interface by the tip. This aims at improving the capability of pressing a button and the robot intrinsic safety (to ensure the kinematic movement was achieved or that the arm would not move in a self destructive manner). The performance of the system was also enhanced by adding a “touch-pen stylus” as a tip of the robotic arm. Using such a system, the likelihood of getting indirectly (i.e., because deposited on surfaces) infected with SARS-CoV-2 or other viruses and/or bacteria is extremely reduced. To the authors’ best knowledge, this is the first attempt of its kind. In literature, in fact, there are several descriptions of robots for different healthcare and infection, prevention, and control purposes, spanning from their use for automatised disinfection, to the control of hand sanitising practices, and to the management of patients. In particular, the robots described by Kraft [ 7 ], Miseikis et al. [ 9 ], Lanza et al. [ 10 ] focus on the assistance of people and patients, and on human interaction. The robot introduced by Wang et al. [ 16 ] is only aimed at working on elevators and not at infection, prevention, and control purposes, and uses different principles from ours. The robot introduced by Yang et al. [ 13 ] brings together robotics and telemedicine and is designed to be used in isolation wards for the visit of patients. Our robot was designed bearing in mind the medical device regulations and their strict requirements about risk analysis, evaluation and management, as duly explained in ISO 13485 (Quality Management Systems) and ISO 14971 (Medical devices - Application of risk management to medical devices). For the low-level and low-cost technologies that we have employed, our results were satisfactory. Better results could be gained just improving the underlying technologies. The cross-platform mobile app results to work properly and to communicate without any issues with Arduino, via Bluetooth, but it could be easily improved with further features. Optimization measures have been carried out in order to improve the prototype effectiveness. A “touch-pen stylus” have been mounted on the robotic arm with the aim of improving the capability of pressing a button. With reference to future improvements and development, we can summarize some possibilities. Regarding the structure of the system, it could be appropriate to design and develop a linear guide on which to mount the robot base, in order to allow interaction with larger interfaces or horizontal-emphasis interface. Moreover, a bigger robotic arm model, requiring proper servo and stepper motors (with higher torque powers) could improve the interaction range. Higher DOF would be advisable with the aim of developing further functions, such as that of turning a knob, moving a slider, switching a toggle or pulling a lever. For this purpose it could be useful to design and develop a custom robotic tip capable of accomplishing those mentioned multiple functions, with the same efficacy. With reference to the remote control of the system, it could be appropriate to program a more performing micro-controller, for instance STM32 Nucleo boards, in order to provide improved UI experience. Even the development of a webserver, in which to save different keypad replicates and from which to retrieve them via the mobile app, would add value to the whole system. In this case, the development of a specific subsystem, in the mobile app, would be necessary to communicate with the webserver.

Conclusions

The current COVID-19 pandemic, characterized by remarkable severity and diffusion, has been without equal in modern history. The tragic times caused by COVID-19, showed how crucial, ingenious, and resilient are healthcare and essential worker, worldwide. In light of this, with this work, we brought forward a project dealing with a robotic system that could immediately be useful to the healthcare system, healthcare workers, and society, during the current and likely future pandemics/epidemics. Indeed, the safe and efficient progress of healthcare does not only rely on medicine, but also on engineering, science and technology. This paper illustrates the design of a device conceived for avoiding direct contact between users and interfaces of selected medical equipment and/or of interfaces of civilian use. Our prototype is composed of two main components: an automated/robotic system, driven by a micro-controller, and a mobile phone app that remotely communicates with the micro-controller. Therefore, it is possible to manage the medical equipment or interface for civilian use from long distance through a wireless connection, using Bluetooth or WiFi technologies. The point of strength of our approach, also presented in this paper, is the PHA that we carried out on the conceived device and that guided our design phase. This step was essential to be compliant with the stringent requirements for risk analysis, assessment, and management of ISO 13485, ISO 14971, and of the European Medical Device Regulations (2017/745) ( https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX%3A32017R0745 ). Such regulations and standards, specifically the latter, would have to be applied in case our system were to be used together with a medical device to pursue a medical intended purpose.

Open access funding provided by Università degli Studi di Siena within the CRUI-CARE Agreement.

This article is part of the COVID-19 Health Technology: Design, Regulation, Management, Assessment

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Contributor Information

Ernesto Iadanza, Email: [email protected] .

Giammarco Pasqua, Email: [email protected] .

Davide Piaggio, Email: [email protected] .

Corrado Caputo, Email: [email protected] .

Monica Gherardelli, Email: [email protected] .

Leandro Pecchia, Email: [email protected] .

Academia.edu no longer supports Internet Explorer.

To browse Academia.edu and the wider internet faster and more securely, please take a few seconds to  upgrade your browser .

Enter the email address you signed up with and we'll email you a reset link.

  • We're Hiring!
  • Help Center

paper cover thumbnail

Design, Analysis and Implementation of a Robotic Arm- The Animator

Profile image of Alimul Khan

A humanoid robotics is a new challenging field. To co-operate with human beings, humanoid robots not only have to feature human like form and structure, but more importantly, they must prepared human like behavior regarding the motion, communication and intelligence. The model number of this beginner is ASR K-250. This paper we consider the mechanism and mechanical structure of ASR K-250 (Beginner) and its implementation.

Related Papers

International Journal of Advanced Research in Science, Communication and Technology

Shreyansh Patel

research paper for robot arm

International Journal of Humanoid Robotics

SeoWook .Park

The mechanical and electrical system designs and system integration including controllers and sensory devices of the humanoid KHR-2 are presented. The design concept and the objective are also discussed. Since 2003, we have been developing KHR-2, which has 41 DOF (degrees of freedom). Each arm of KHR-2 has 11 DOF in total: 5 DOF/hand (i.e. fingers), 2 DOF/wrist, and 4 DOF/arm. Each leg constitutes 6 DOF. The head constitutes 6 DOF (2 DOF for eyes and 2 DOF at the neck), and the trunk has 1 DOF. KHR-2 has been mechanically designed to have a human friendly appearance and also wide ranges of angular motion. Its joint actuators have been designed in order to reduce motion uncertainties such as backlash. All axes of KHR-2 are under distributed control, which reduces the computational burden on the main controller and also to facilitate device expansions. We have developed a microprocessor-based sub-controller for servo motor operations, onto which sensory feedback is interfaced. The mai...

Kaushal Dholariya

The humanoid robots are necessarily to be developed because of its ability to perform variety of tasks in flexible environment. This paper presents the conceptual design, kinematic analysis and development of voice control system of the proposed 14 Degree of Freedom (DOF) humanoid robot (AKSHAR). The forward kinematics of the humanoid arm is done by (DH) method. Generally, the inverse kinematics of humanoid robot is mostly non-linear and difficult to solve. To overcome this issue, the elbow and wrist are considered as coupled link because of their relative motion which leads to solve the problem with less complexity. A comparative study is carried out between geometry and Adaptive Neuro-Fuzzy Inference system (ANFIS) methods to find a suitable approach to solve inverse kinematics of the robot. Further, in order to improve the humanoid design, the voice control system using Bluetooth is developed to interact with human. The main focus of the research is to carry out accurate solutions for inverse kinematics by using an advance approach so that the results data will be implemented and trained to the robot to grasp the object successively. Based on the inverse kinematics solutions, the developed ANFIS solution using MATLAB shows better results than geometry method. The developed voice controlled system found to be satisfactory with the given inputs.

Ruediger Dillmann

International Journal of ADVANCED AND APPLIED SCIENCES

Faisal Shafique Butt

Proceedings of the …

Gordon Wyeth

2013 IEEE International Conference on Mechatronics and Automation

Sumit Gupta

International Journal of Engineering Research and Technology (IJERT)

IJERT Journal

https://www.ijert.org/humanoid-robot https://www.ijert.org/research/humanoid-robot-IJERTV2IS110118.pdf Robot programming has always been a central topic in industrial robotics as well as in robotics research. Classical teaching is still widespread and with many robots the programmers still press buttons for left, fight, up, down etc. Off-line programming does not solve this problem, as in the 3D-graphics world , too, one has to move the robot somewhere in 6 degrees of freedom. On the other hand more than 50 programming languages have been developed without yielding a real breakthrough. Thus after more than 25 years in robotics research we are fairly sure that learning by showing and/or direct guidance and intuitive interaction remains one of the most promising techniques in robot programming. If we are talking about service and human friendly robots, intuitive interaction is the key issue. It seems that there are three major alternatives for intuitive man-robot interaction: voice; human hand; and human face. It is outlined in which way these techniques so far have entered the programming of industrial robots but especially the remote control of space and surgical robots. In our project we are attaching 1 accelerometer to the hand which will detect the ARM's position in Forward, Reverse, left, right, grab, release etc.

Control Automation and …

Akhtaruzzaman Akhter

Loading Preview

Sorry, preview is currently unavailable. You can download the paper by clicking the button above.

RELATED PAPERS

Rudiger Dillmann

Humanoid Robots, Human-like Machines

Irraivan Elamvazuthi

Mathematical Modelling of Engineering Problems

Deepak Bharadwaj

Britta Wrede

International Journal of Innovative Technology and Exploring Engineering

Shifa Sulaiman

Blucher Engineering Proceedings

Matheus França

Lecture Notes in Control and Information Sciences

Krzysztof Mianowski

Jacky Baltes

Dimitar Chakarov

Prakash Sen

Autonomous Robots

Shigeki Sugano

marco maggiali

… , 2006. BioRob 2006. …

Giuseppe Carbone

Proceedings of the 6th International Conference on Informatics in Control, Automation and Robotics

Lecture Notes in Computer Science

António Neves

Modelling Human Motion

Tiago Ribeiro

New Trends in Medical and Service Robots

Sci. Aleksandar D. Rodic

The International Journal of Robotics Research

Kazuhito Yokoi , Fumio Kanehiro

RELATED TOPICS

  •   We're Hiring!
  •   Help Center
  • Find new research papers in:
  • Health Sciences
  • Earth Sciences
  • Cognitive Science
  • Mathematics
  • Computer Science
  • Academia ©2024

IEEE Account

  • Change Username/Password
  • Update Address

Purchase Details

  • Payment Options
  • Order History
  • View Purchased Documents

Profile Information

  • Communications Preferences
  • Profession and Education
  • Technical Interests
  • US & Canada: +1 800 678 4333
  • Worldwide: +1 732 981 0060
  • Contact & Support
  • About IEEE Xplore
  • Accessibility
  • Terms of Use
  • Nondiscrimination Policy
  • Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest technical professional organization dedicated to advancing technology for the benefit of humanity. © Copyright 2024 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.

IMAGES

  1. (PDF) Design of 6-Axis robotic arm

    research paper for robot arm

  2. (PDF) 5 Degrees of Freedom Robotic Arm controlled using PS/2 Mouse

    research paper for robot arm

  3. Kinematics Modeling of a 4-DOF Robotic Arm (PDF Download Available)

    research paper for robot arm

  4. The iCub arm. A CAD view of the arm of the iCub robot with superimposed

    research paper for robot arm

  5. (PDF) Design and development of a robotic arm

    research paper for robot arm

  6. Robot Arm

    research paper for robot arm

VIDEO

  1. Mori3

  2. The Paper Robot

  3. paper Robot 🤖#youtubeshorts #trending #sohrtsfeed

  4. Robotic Hand Science Project

  5. Robot Gya Paper Dene😱🤖|| Sahib Singh ||#schoollife #shorts #robot

  6. How to Make a Robotic Arm from Cardboard #shorts #lifehacks

COMMENTS

  1. (PDF) Design and development of a robotic arm

    This paper presents the design and. development of 5-Degree of Freedom (DOF) robotic arm which. is used for feeding the elderly or specially challenged people, where the position of the joints are ...

  2. (PDF) DEVELOPMENT OF A ROBOT ARM: A REVIEW

    manipulator, a robot arm, (according to Park and Lynch, (2016)), has an arm that en sures mobility, a wrist that. confers dexterity, and a n end-effector that performs the task. required of the ...

  3. A multi-objective optimization design of industrial robot arms

    The paper is organized as follows; Section 2 briefly introduces the methodologies and software engines used in this work. The stress analysis is conducted using an analytical approach and FEA simulations as well in Section 3. Section 4 shows the material restructuring of the robot arm according to the vibration analysis. The GA optimization approach is employed to provide efficient power and ...

  4. Design of a Four-Axis Robot Arm System Based on Machine Vision

    With the concept of industrial automation gradually being put forward, the four-axis robotic arm is gradually being applied in industrial production environments due to its advantages such as a stable structure, easy maintenance, and expandability. However, it is difficult to diversify and improve the traditional four-axis robotic arm system due to the high software and hardware coupling and ...

  5. An Automated Robotic Arm: A Machine Learning Approach

    an automatic robotic arm that picks and places objects. This system focuses on the implementation of the concepts of machine learning for deciding the amount of movement that the arm must produce in order to reach and grab the target object. A. System Design The robotic arm is made up of PLA material and is 3D printed.

  6. Design and analysis of a robotic arm under different loading conditions

    A six degrees of freedom robotic arm is designed in this research. The study involves the design and analysis of a material-handling robotic arm. An Arduino Uno microcontroller could be used to regulate this arm. ... The main aim of this paper is to minimize the weight and maximize the weight lifting capacity of the robotic arm. This robotic ...

  7. A Review of Current Techniques for Robotic Arm ...

    Robotic manipulators are widely used in the field of robotics. In this paper, four different manipulators are reviewed, and their use in robotic applications is presented. These robotic implementations and applications continue to evolve to meet an ever-growing industrial need for improved efficiency and functionality. This is a work in progress and the next step of this research is to use the ...

  8. (PDF) A brief survey of commercial robotic arms for research on

    robot is classified as a research arm. Fig. 6. ... and [20] utilized 2-link, 3-link, 5-link, and 6-link mechanisms, respectively, the robotic arm proposed in this paper is a generalized version ...

  9. Development of Robotic Arm Prototype

    A remote-controlled robotic arm is a significant technological advancement that can be used in various fields. This research paper focuses on the development of a remote-controlled robotic arm using Arduino. The paper discusses the construction of the robotic arm and the selection of components such as servo motors and microcontrollers. The live feed of the arm's movements can be controlled ...

  10. Design and Implementation of an Anthropomorphic Robotic Arm ...

    The open-source mechanical design of the presented robotic arm has mass-dimensional and motor parameters close to the human hand, with the possibility of autonomous battery operation, the ability to connect different control systems, such as from a computer, an electroencephalograph, a touch glove. ... Feature papers represent the most advanced ...

  11. Optimization of a Robotic Arm Using Generative Design

    This paper deals with the optimization of a robotic arm in an industrial robot using generative design to minimize the weight of the arm without compensating its rigidity. The industrial robot used for this study is ABB IRB 6660 shown in Fig. 6 and the arm which is to be generated is shown in Fig. 7.

  12. Research of robotic arm control system based on deep learning and 3D

    A robotic arm control system is developed based on deep learning and 3D point cloud target detection algorithm, which can control the operation of the robotic arm based on image recognition and target detection according to the images captured by the camera. ... The research and design of this paper can provide new application prospects for ...

  13. PDF Pick and Place Robotic Arm: A Review Paper

    In this research paper the authors successfully built a 4 degrees of freedom robotic arm using soft computing. They have formulated ways for controlled movement of robotic arm and planning of trajectory with the help of Genetic Algorithms (GAs) and fuzzy logic (FL). As optimal movement is critical for efficient autonomous robots.

  14. (PDF) robot arm project

    Figure (3.1): robot arm diagram. The developed robot in this study is a stationary articulated robotic arm with 5 DOF. which includes base, shoulder, elbow, gripper, including two revolute joints ...

  15. A robotic arm for safe and accurate control of biomedical equipment

    The robotic-arm model was chosen as best solution due to its versatility and adaptability to the most diversified situations and environments. To achieve this, at first, we conducted a research of ready-made robotic arms available on the web and we chose a four Degree-of-Freedom (DOF) model, easily purchased in the main online seller and ...

  16. Design of a Controlled Robotic Arm

    This paper presents a design of controlled robotic arm with myoelectric and body action signals. The implementation uses the sensed signals, via the signal processing of ARDUINO UNO R3 development board and NUC140VE3CN development board (ARM processor), to control the robotic arm wirelessly. The proposed design can be used in the dangerous operation environment. The users can contactlessly ...

  17. PDF Design and Analysis of An Articulated Robot Arm for Various Industrial

    Unlike earlier robots in science fiction, robots do not threaten humans since Asimov invented the three laws of robotics: 1. A robot may not harm a human or, through inaction, allow a human to come to harm. 2. A robot must obey the orders given by human beings, except when such orders conflict with the First Law. 3.

  18. (PDF) Current Designs of Robotic Arm Grippers: A Comprehensive

    1 Department of Mechanical Engineering, University of Wisconsin-Milwaukee, Milwaukee, WI 53212, USA. 2 Department of Computer Science, University of Wisconsin-Milwaukee, Milwaukee, WI 53212, USA ...

  19. (PDF) Design, Analysis and Implementation of a Robotic Arm- The

    Introduction: The application of robotics field is broadly used in the field of research, laboratory based work, industrial work to automate process and reduce the human errors. This paper is describing the design of mechanical structure of a robotic arm. This robotic arm is often indicated to move an object from one place to another place.

  20. Design and development of a robotic arm

    Demand for assistive robots are increasing as they allow individuals to work independently and perform tasks that are impossible without them. This paper presents the design and development of 5-Degree of Freedom (DOF) robotic arm which is used for feeding the elderly or specially challenged people, where the position of the joints are controlled by the user. Using principles of robotic ...

  21. PDF Automated Guided Vehicles with Robotic Arm: Enhancing Efficiency and

    This research paper delves into the integration of robotic arms into AGVs, providing an in - depth analysis of the benefits, challenges, and potential applications of this technology. The paper explores the underlying technologies, including navigation systems, perception sensors, and robotic arm control, that enable

  22. Design and Development of Pick and Place Arm Robot

    The robot arm is designed with simple design where the transformation of the components is carried out using the pneumatic cylinders and the suction grippers. ... research paper and also wish to ...

  23. (PDF) Vision-Based Robotic Arm Control Algorithm Using Deep

    Thereby, in this paper, we propose a deep deterministic policy gradient approach that can be applied to a numerous-degrees-of-freedom robotic arm towards autonomous objects grasping according to ...